Форма представления | Статьи в российских журналах и сборниках |
Год публикации | 2004 |
Язык | английский |
|
Будников Герман Константинович, автор
Зиятдинова Гузель Камилевна, автор
|
|
Валитова Яна Раисовна, автор
|
Библиографическое описание на языке оригинала |
Budnikov G.K, Ziyatdinova G.K, Valitova Ya.R., Electrochemical determination of glutathione//Journal of Analytical Chemistry. - 2004. - Vol.59, Is.6. - P.573-576. |
Аннотация |
Procedures were developed for determining glutathione by voltammetry and coulometric titration
with electrogenerated oxidants using the biamperometric indication of the titration end-point. Possible mechanisms of the glutathione reaction with electrogenerated halogens are discussed. Microgram amounts of glutathione can be determined in model solutions with an RSD of 1?2%. The oxidation wave of glutathione in the voltammogram is observed at 0.95 V. At higher glutathione concentrations, the wave takes the shape of a peak. Glutathione concentration in the range between 9.15×10(?5) and 2.14×10(?3) M is a linear function of its oxidation wave height at a stationary platinum electrode in a 0.05 M H2SO4 solution. The determination limit for glutathione is 1.9×10(?5) M. The procedures for determining glutathione in human blood were proposed. |
Ключевые слова |
Coulometric titration, voltammetry, glutathione, blood, biomedical analysis |
Название журнала |
JOURNAL OF ANALYTICAL CHEMISTRY
|
URL |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-3042795454&partnerID=40&md5=f0e130274f2c5bfaedc3103203a392bd |
Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на эту карточку |
https://repository.kpfu.ru/?p_id=134876 |
Полная запись метаданных |
Поле DC |
Значение |
Язык |
dc.contributor.author |
Будников Герман Константинович |
ru_RU |
dc.contributor.author |
Зиятдинова Гузель Камилевна |
ru_RU |
dc.contributor.author |
Валитова Яна Раисовна |
ru_RU |
dc.date.accessioned |
2004-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2004-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2004 |
ru_RU |
dc.identifier.citation |
Budnikov G.K, Ziyatdinova G.K, Valitova Ya.R., Electrochemical determination of glutathione//Journal of Analytical Chemistry. - 2004. - Vol.59, Is.6. - P.573-576. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/?p_id=134876 |
ru_RU |
dc.description.abstract |
JOURNAL OF ANALYTICAL CHEMISTRY |
ru_RU |
dc.description.abstract |
Procedures were developed for determining glutathione by voltammetry and coulometric titration
with electrogenerated oxidants using the biamperometric indication of the titration end-point. Possible mechanisms of the glutathione reaction with electrogenerated halogens are discussed. Microgram amounts of glutathione can be determined in model solutions with an RSD of 1?2%. The oxidation wave of glutathione in the voltammogram is observed at 0.95 V. At higher glutathione concentrations, the wave takes the shape of a peak. Glutathione concentration in the range between 9.15×10(?5) and 2.14×10(?3) M is a linear function of its oxidation wave height at a stationary platinum electrode in a 0.05 M H2SO4 solution. The determination limit for glutathione is 1.9×10(?5) M. The procedures for determining glutathione in human blood were proposed. |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
Coulometric titration |
ru_RU |
dc.subject |
voltammetry |
ru_RU |
dc.subject |
glutathione |
ru_RU |
dc.subject |
blood |
ru_RU |
dc.subject |
biomedical analysis |
ru_RU |
dc.title |
Electrochemical determination of glutathione |
ru_RU |
dc.type |
Статьи в российских журналах и сборниках |
ru_RU |
|