Форма представления | Статьи в российских журналах и сборниках |
Год публикации | 2004 |
Язык | английский |
|
Будников Герман Константинович, автор
Зиятдинова Гузель Камилевна, автор
|
|
Погорельцев Валерий Ильич, автор
|
Библиографическое описание на языке оригинала |
Ziyatdinova G.K, Budnikov G.K, Pogorel'tsev V.I., Electrochemical determination of lipoic acid//Journal of Analytical Chemistry. - 2004. - Vol.59, Is.3. - P.288-290. |
Аннотация |
Procedures for determining lipoic acid by voltammetry and coulometric titration with electrogenerated halogens using the biamperometric indication of the titration end-point were developed. Possible mechanisms
of lipoic acid oxidation with electrogenerated halogens are discussed. Microgram amounts of lipoic acid were determined in model solutions with an RSD of 1?2%. The analytical range of lipoic acid found by voltammetry
at a glassy-carbon electrode lies between 1.15X10?5 and 1.73X10?4 M. The detection limit for lipoic acid is 5.75X10?6 M. |
Ключевые слова |
Coulometric titration, voltammetry, lipoic acid |
Название журнала |
JOURNAL OF ANALYTICAL CHEMISTRY
|
URL |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-3543004728&partnerID=40&md5=2204fb0893c296d33f96ca6543b807fa |
Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на эту карточку |
https://repository.kpfu.ru/?p_id=134877 |
Полная запись метаданных |
Поле DC |
Значение |
Язык |
dc.contributor.author |
Будников Герман Константинович |
ru_RU |
dc.contributor.author |
Зиятдинова Гузель Камилевна |
ru_RU |
dc.contributor.author |
Погорельцев Валерий Ильич |
ru_RU |
dc.date.accessioned |
2004-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2004-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2004 |
ru_RU |
dc.identifier.citation |
Ziyatdinova G.K, Budnikov G.K, Pogorel'tsev V.I., Electrochemical determination of lipoic acid//Journal of Analytical Chemistry. - 2004. - Vol.59, Is.3. - P.288-290. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/?p_id=134877 |
ru_RU |
dc.description.abstract |
JOURNAL OF ANALYTICAL CHEMISTRY |
ru_RU |
dc.description.abstract |
Procedures for determining lipoic acid by voltammetry and coulometric titration with electrogenerated halogens using the biamperometric indication of the titration end-point were developed. Possible mechanisms
of lipoic acid oxidation with electrogenerated halogens are discussed. Microgram amounts of lipoic acid were determined in model solutions with an RSD of 1?2%. The analytical range of lipoic acid found by voltammetry
at a glassy-carbon electrode lies between 1.15X10?5 and 1.73X10?4 M. The detection limit for lipoic acid is 5.75X10?6 M. |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
Coulometric titration |
ru_RU |
dc.subject |
voltammetry |
ru_RU |
dc.subject |
lipoic acid |
ru_RU |
dc.title |
Electrochemical determination of lipoic acid |
ru_RU |
dc.type |
Статьи в российских журналах и сборниках |
ru_RU |
|