Форма представления | Статьи в зарубежных журналах и сборниках |
Год публикации | 2017 |
Язык | английский |
|
Ходов Илья Анатольевич, автор
|
Библиографическое описание на языке оригинала |
Khodov I.A., Accuracy of determination of self-diffusion coefficients in studies of porphyrin-based complexes by 2D DOSY//Macroheterocycles. - 2017. - Vol.10, Is.3. - P.313-316. |
Аннотация |
Influence of chemical exchange processes on the accuracy of determination of self-diffusion complexes of porphyrinnickel complexes was shown. A method of estimating the inaccuracy of the self-diffusion coefficients for an inverted porphyrin complex was proposed. The values obtained using two different approaches to recording DOSY spectra, STE and CPMG, were compared. Allowing for exchange was shown to be important for accurate diffusion measurements and correct interpretation of results obtained in studied of molecular-level processes. ? ISUCT Publishing. |
Ключевые слова |
2D DOSY, Chemical exchange, J-modulation, N-confused porphyrins, NMR, Self-diffusion coefficients. |
Название журнала |
Macroheterocycles
|
URL |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85038111591&doi=10.6060%2fmhc170200k&partnerID=40&md5=ad24d5aff28c841be00eae481b75267f |
Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на эту карточку |
https://repository.kpfu.ru/?p_id=184175 |
Полная запись метаданных |
Поле DC |
Значение |
Язык |
dc.contributor.author |
Ходов Илья Анатольевич |
ru_RU |
dc.date.accessioned |
2017-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2017-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2017 |
ru_RU |
dc.identifier.citation |
Khodov I.A., Accuracy of determination of self-diffusion coefficients in studies of porphyrin-based complexes by 2D DOSY//Macroheterocycles. - 2017. - Vol.10, Is.3. - P.313-316. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/?p_id=184175 |
ru_RU |
dc.description.abstract |
Macroheterocycles |
ru_RU |
dc.description.abstract |
Influence of chemical exchange processes on the accuracy of determination of self-diffusion complexes of porphyrinnickel complexes was shown. A method of estimating the inaccuracy of the self-diffusion coefficients for an inverted porphyrin complex was proposed. The values obtained using two different approaches to recording DOSY spectra, STE and CPMG, were compared. Allowing for exchange was shown to be important for accurate diffusion measurements and correct interpretation of results obtained in studied of molecular-level processes. ? ISUCT Publishing. |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
2D DOSY |
ru_RU |
dc.subject |
Chemical exchange |
ru_RU |
dc.subject |
J-modulation |
ru_RU |
dc.subject |
N-confused porphyrins |
ru_RU |
dc.subject |
NMR |
ru_RU |
dc.subject |
Self-diffusion coefficients. |
ru_RU |
dc.title |
Accuracy of determination of self-diffusion coefficients in studies of porphyrin-based complexes by 2D DOSY |
ru_RU |
dc.type |
Статьи в зарубежных журналах и сборниках |
ru_RU |
|