Форма представления | Статьи в зарубежных журналах и сборниках |
Год публикации | 2021 |
Язык | английский |
|
Евтюгин Геннадий Артурович, автор
Краснова Татьяна Николаевна, автор
Порфирьева Анна Вениаминовна, автор
Рогов Алексей Михайлович, автор
|
Библиографическое описание на языке оригинала |
Kulikova T., Porfireva A., Rogov A., Evtugyn G. (2021) Electrochemical DNA sensor based on acridine yellow adsorbed on glassy carbon electrode. Sensors, 21(22):7763. https://doi.org/10.3390/s21227763 |
Аннотация |
Electrochemical DNA sensors offer unique opportunities for the sensitive detection of specific DNA interactions. In this work, a voltametric DNA sensor is proposed on the base of glassy carbon electrode modified with carbon black, adsorbed acridine yellow and DNA for highly sensitive determination of doxorubicin antitumor drug. The signal recorded by cyclic voltammetry was attributed to irreversible oxidation of the dye. Its value was altered by aggregation of the hydrophobic dye molecules on the carbon black particles. DNA molecules promote disaggregation of the dye and increased the signal. This effect was partially suppressed by doxorubicin compensate for the charge of DNA in the intercalation. Sensitivity of the signal toward DNA and doxorubicin was additionally increased by treatment of the layer with dimethylformamide. In optimal conditions, the linear range of doxorubicin concentrations determined was 0.1 pM–1.0 nM, and the detection limit was 0.07 pM. No influence of sulfonamide medicines and plasma electrolytes on the doxorubicin determination was shown. The DNA sensor was tested on two medications (doxorubicin-TEVA and doxorubicin-LANS) and showed recoveries of 102–105%. The DNA sensor developed can find applications in the determination of drug residues in blood and for the pharmacokinetics studies |
Ключевые слова |
Carbon black, Cyclic voltammetry, Doxorubicin determination, Drug determination, Electrochemical DNA sensor |
Название журнала |
Sensors
|
URL |
https://doi.org/10.3390/s21227763 |
Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на эту карточку |
https://repository.kpfu.ru/?p_id=272319 |
Файлы ресурса | |
|
Полная запись метаданных |
Поле DC |
Значение |
Язык |
dc.contributor.author |
Евтюгин Геннадий Артурович |
ru_RU |
dc.contributor.author |
Краснова Татьяна Николаевна |
ru_RU |
dc.contributor.author |
Порфирьева Анна Вениаминовна |
ru_RU |
dc.contributor.author |
Рогов Алексей Михайлович |
ru_RU |
dc.date.accessioned |
2021-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2021-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2021 |
ru_RU |
dc.identifier.citation |
Kulikova T., Porfireva A., Rogov A., Evtugyn G. (2021) Electrochemical DNA sensor based on acridine yellow adsorbed on glassy carbon electrode. Sensors, 21(22):7763. https://doi.org/10.3390/s21227763 |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/?p_id=272319 |
ru_RU |
dc.description.abstract |
Sensors |
ru_RU |
dc.description.abstract |
Electrochemical DNA sensors offer unique opportunities for the sensitive detection of specific DNA interactions. In this work, a voltametric DNA sensor is proposed on the base of glassy carbon electrode modified with carbon black, adsorbed acridine yellow and DNA for highly sensitive determination of doxorubicin antitumor drug. The signal recorded by cyclic voltammetry was attributed to irreversible oxidation of the dye. Its value was altered by aggregation of the hydrophobic dye molecules on the carbon black particles. DNA molecules promote disaggregation of the dye and increased the signal. This effect was partially suppressed by doxorubicin compensate for the charge of DNA in the intercalation. Sensitivity of the signal toward DNA and doxorubicin was additionally increased by treatment of the layer with dimethylformamide. In optimal conditions, the linear range of doxorubicin concentrations determined was 0.1 pM–1.0 nM, and the detection limit was 0.07 pM. No influence of sulfonamide medicines and plasma electrolytes on the doxorubicin determination was shown. The DNA sensor was tested on two medications (doxorubicin-TEVA and doxorubicin-LANS) and showed recoveries of 102–105%. The DNA sensor developed can find applications in the determination of drug residues in blood and for the pharmacokinetics studies |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
Carbon black |
ru_RU |
dc.subject |
Cyclic voltammetry |
ru_RU |
dc.subject |
Doxorubicin determination |
ru_RU |
dc.subject |
Drug determination |
ru_RU |
dc.subject |
Electrochemical DNA sensor |
ru_RU |
dc.title |
Electrochemical DNA sensor based on acridine yellow adsorbed on glassy carbon electrode |
ru_RU |
dc.type |
Статьи в зарубежных журналах и сборниках |
ru_RU |
|