Shlyamina, O.V. Use of galvanostatic coulometry for determining nitroxoline / O.V. Shlyamina, G.K. Ziyatdinova, S.G. Abdullina, G.K. Budnikov // J. Anal. Chem. - 2007. - V. 62. - No. 10. - P. 957-959. |
Аннотация |
It was found that nitroxoline rapidly and quantitatively reacts with electrogenerated chlorine or bromine. The stoichiometric coefficients of these reactions are 1 : 1.5 and 1 : 1, respectively. The mechanism of the reaction of nitroxoline with electrogenerated bromine was proposed. A procedure was developed for the quantitative determination of nitroxoline in the substance and pharmaceuticals with a relative standard deviation of 1?3%. |
Ключевые слова |
Nitroxoline, galvanostatic coulometry, electrogenerated halogens, pharmaceutical analysis |
Название журнала |
J ANALCHEM+
|
URL |
http://link.springer.com/article/10.1134%2FS1061934807100103 |
Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на эту карточку |
https://repository.kpfu.ru/?p_id=66649 |
Полная запись метаданных |
Поле DC |
Значение |
Язык |
dc.contributor.author |
Будников Герман Константинович |
ru_RU |
dc.contributor.author |
Зиятдинова Гузель Камилевна |
ru_RU |
dc.contributor.author |
Абдуллина Светлана Геннадиевна |
ru_RU |
dc.contributor.author |
Шлямина Оксана Викторовна |
ru_RU |
dc.date.accessioned |
2007-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2007-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2007 |
ru_RU |
dc.identifier.citation |
Shlyamina, O.V. Use of galvanostatic coulometry for determining nitroxoline / O.V. Shlyamina, G.K. Ziyatdinova, S.G. Abdullina, G.K. Budnikov // J. Anal. Chem. - 2007. - V. 62. - No. 10. - P. 957-959. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/?p_id=66649 |
ru_RU |
dc.description.abstract |
J ANALCHEM+ |
ru_RU |
dc.description.abstract |
It was found that nitroxoline rapidly and quantitatively reacts with electrogenerated chlorine or bromine. The stoichiometric coefficients of these reactions are 1 : 1.5 and 1 : 1, respectively. The mechanism of the reaction of nitroxoline with electrogenerated bromine was proposed. A procedure was developed for the quantitative determination of nitroxoline in the substance and pharmaceuticals with a relative standard deviation of 1?3%. |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
Nitroxoline |
ru_RU |
dc.subject |
galvanostatic coulometry |
ru_RU |
dc.subject |
electrogenerated halogens |
ru_RU |
dc.subject |
pharmaceutical analysis |
ru_RU |
dc.title |
Use of galvanostatic coulometry for determining nitroxoline |
ru_RU |
dc.type |
Статьи в российских журналах и сборниках |
ru_RU |
|