Evtugyn, G. Electrochemical biosensors based on native DNA and nanosized mediator for the detection of anthracycline preparations [Text] / G.Evtugyn, A.Porfireva, V.Stepanova, H.Budnikov // Electroanalysis- 2015.- V.27, N2.- P.629-637. |
Annotation |
A novel electrochemical DNA-sensor based on glassy carbon electrode (GCE) modified with electropolymerized Neutral red (NR) and polycarboxylated thiacax[4]arene with covalently attached mediator and electrostatically adsorbed DNA was developed for sensitive detection of anthracycline preparations. Intercalation of doxorubicin, daunorubicin and idarubicin into DNA increases the charge transfer resistance and decreases the electron exchange resulted in decay of the cathodic peak of NR reduction. The DNA-sensor developed makes it possible to determine down to 0.05 nM doxorubicin, o.1 nM doxorubicin and 0.5 nM idarubicin. The DNA-sensor was tested on detection of doxorubicin in pharmaceuticals and artificial blood plasma with 95?100 % recovery. |
Keywords |
DNA sensor, Anthracycline pharmaceuticals, Poly(Neutral red), Nanosized mediator, Electrochemical impedance |
The name of the journal |
ELECTROANAL
|
URL |
http://onlinelibrary.wiley.com/doi/10.1002/elan.201400564/abstract |
Please use this ID to quote from or refer to the card |
https://repository.kpfu.ru/eng/?p_id=104406&p_lang=2 |
Full metadata record |
Field DC |
Value |
Language |
dc.contributor.author |
Budnikov German Konstantinovich |
ru_RU |
dc.contributor.author |
Evtyugin Gennadiy Arturovich |
ru_RU |
dc.contributor.author |
Porfireva Anna Veniaminovna |
ru_RU |
dc.contributor.author |
Stepanova Veronika Borisovna |
ru_RU |
dc.date.accessioned |
2015-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2015-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2015 |
ru_RU |
dc.identifier.citation |
Evtugyn, G. Electrochemical biosensors based on native DNA and nanosized mediator for the detection of anthracycline preparations [Text] / G.Evtugyn, A.Porfireva, V.Stepanova, H.Budnikov // Electroanalysis- 2015.- V.27, N2.- P.629-637. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/eng/?p_id=104406&p_lang=2 |
ru_RU |
dc.description.abstract |
ELECTROANAL |
ru_RU |
dc.description.abstract |
A novel electrochemical DNA-sensor based on glassy carbon electrode (GCE) modified with electropolymerized Neutral red (NR) and polycarboxylated thiacax[4]arene with covalently attached mediator and electrostatically adsorbed DNA was developed for sensitive detection of anthracycline preparations. Intercalation of doxorubicin, daunorubicin and idarubicin into DNA increases the charge transfer resistance and decreases the electron exchange resulted in decay of the cathodic peak of NR reduction. The DNA-sensor developed makes it possible to determine down to 0.05 nM doxorubicin, o.1 nM doxorubicin and 0.5 nM idarubicin. The DNA-sensor was tested on detection of doxorubicin in pharmaceuticals and artificial blood plasma with 95?100 % recovery. |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
DNA sensor |
ru_RU |
dc.subject |
Anthracycline pharmaceuticals |
ru_RU |
dc.subject |
Poly(Neutral red) |
ru_RU |
dc.subject |
Nanosized mediator |
ru_RU |
dc.subject |
Electrochemical impedance |
ru_RU |
dc.title |
Electrochemical biosensors based on native DNA and nanosized mediator for the detection of anthracycline preparations. |
ru_RU |
dc.type |
Articles in international journals and collections |
ru_RU |
|