Form of presentation | Articles in international journals and collections |
Year of publication | 2016 |
Язык | английский |
|
Budnikov German Konstantinovich, author
Guss Ekaterina Valerevna, author
Ziyatdinova Guzel Kamilevna, author
|
|
Guss Ekaterina Valerevna, postgraduate kfu
|
Bibliographic description in the original language |
Ziyatdinova G. Chronocoulometry of wine on multi-walled carbon nanotube modified electrode: antioxidant capacity assay / G. Ziyatdinova, E. Kozlova, H. Budnikov // Food Chem. - 2016. - V.196. - P.405-410. |
Annotation |
Phenolic antioxidants of wine were electrochemically oxidized on multi-walled carbon nanotubes modified glassy carbon electrode (MWNT/GCE) in phosphate buffer solution. Three oxidation peaks were observed at 0.39, 0.61 and 0.83 V for red dry wine and 0.39, 0.80 and 1.18 V for white dry wine, respectively, using differential pulse voltammetry at pH 4.0. The oxidation potentials for individual phenolic antioxidants confirmed the integral nature of the analytical signals for the wines examined. A one-step chronocoulometric method at 0.83 and 1.18 V for red and white wines, respectively, has been developed for the evaluation of wine antioxidant capacity (AOC). The AOC is expressed in gallic acid equivalents per 1 L of wine. The AOC of white wine was significantly less than red wine (386+/-112 vs. 1224+/-184, p < 0.0001), as might be expected. Positive correlations were observed between gallic acid equivalent AOC of wine and total antioxidant capacity. |
Keywords |
Differential pulse voltammetry, Chronocoulometry, Carbon nanotubes, Polyphenols, Antioxidant capacity, Wine, Food analysis. |
The name of the journal |
FOOD CHEMISTRY
|
URL |
http://www.scopus.com/inward/record.url?eid=2-s2.0-84942316550&partnerID=40&md5=5582bf04e154f52073eef2963001879e |
Please use this ID to quote from or refer to the card |
https://repository.kpfu.ru/eng/?p_id=121462&p_lang=2 |
Full metadata record |
Field DC |
Value |
Language |
dc.contributor.author |
Budnikov German Konstantinovich |
ru_RU |
dc.contributor.author |
Guss Ekaterina Valerevna |
ru_RU |
dc.contributor.author |
Ziyatdinova Guzel Kamilevna |
ru_RU |
dc.contributor.author |
Guss Ekaterina Valerevna |
ru_RU |
dc.date.accessioned |
2016-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2016-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2016 |
ru_RU |
dc.identifier.citation |
Ziyatdinova G. Chronocoulometry of wine on multi-walled carbon nanotube modified electrode: antioxidant capacity assay / G. Ziyatdinova, E. Kozlova, H. Budnikov // Food Chem. - 2016. - V.196. - P.405-410. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/eng/?p_id=121462&p_lang=2 |
ru_RU |
dc.description.abstract |
FOOD CHEMISTRY |
ru_RU |
dc.description.abstract |
Phenolic antioxidants of wine were electrochemically oxidized on multi-walled carbon nanotubes modified glassy carbon electrode (MWNT/GCE) in phosphate buffer solution. Three oxidation peaks were observed at 0.39, 0.61 and 0.83 V for red dry wine and 0.39, 0.80 and 1.18 V for white dry wine, respectively, using differential pulse voltammetry at pH 4.0. The oxidation potentials for individual phenolic antioxidants confirmed the integral nature of the analytical signals for the wines examined. A one-step chronocoulometric method at 0.83 and 1.18 V for red and white wines, respectively, has been developed for the evaluation of wine antioxidant capacity (AOC). The AOC is expressed in gallic acid equivalents per 1 L of wine. The AOC of white wine was significantly less than red wine (386+/-112 vs. 1224+/-184, p < 0.0001), as might be expected. Positive correlations were observed between gallic acid equivalent AOC of wine and total antioxidant capacity. |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
Differential pulse voltammetry |
ru_RU |
dc.subject |
Chronocoulometry |
ru_RU |
dc.subject |
Carbon nanotubes |
ru_RU |
dc.subject |
Polyphenols |
ru_RU |
dc.subject |
Antioxidant capacity |
ru_RU |
dc.subject |
Wine |
ru_RU |
dc.subject |
Food analysis. |
ru_RU |
dc.title |
Chronocoulometry of wine on multi-walled carbon nanotube modified electrode: Antioxidant capacity assay |
ru_RU |
dc.type |
Articles in international journals and collections |
ru_RU |
|