Form of presentation | Articles in Russian journals and collections |
Year of publication | 2006 |
Язык | английский |
|
Budnikov German Konstantinovich, author
Ziyatdinova Guzel Kamilevna, author
|
|
Pogorelcev Valeriy Ilich, author
|
Bibliographic description in the original language |
Ziyatdinova, G.K.Determination of captopril in pharmaceutical forms by stripping voltammetry / G.K. Ziyatdinova, G.K. Budnikov, V.I. Pogorel'tsev // J. Anal. Chem. - 2006. - V. 61, No.8.- P.798-800. |
Annotation |
A voltammetric procedure is developed for determining captopril in pharmaceuticals. It is based on the preliminary electrochemical accumulation of the captopril oxidation product on a platinum electrode in a 0.1 M HNO3 solution at 1.2 V versus a saturated silver?silver chloride electrode. The reduction current of the oxidation product is a linear function of captopril concentration in the range from 1.2×10(?6) to 3.2×10(?4) M. The determination limit is 9.2×10(?7) M. The relative standard deviation is between 1 and 4%. |
Keywords |
Stripping voltammetry, captopril, pharmaceutical analysis |
The name of the journal |
JOURNAL OF ANALYTICAL CHEMISTRY
|
URL |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-33746609411&partnerID=40&md5=64ae21dddc4f734247b8eec47c884ac8 |
Please use this ID to quote from or refer to the card |
https://repository.kpfu.ru/eng/?p_id=134870&p_lang=2 |
Full metadata record |
Field DC |
Value |
Language |
dc.contributor.author |
Budnikov German Konstantinovich |
ru_RU |
dc.contributor.author |
Ziyatdinova Guzel Kamilevna |
ru_RU |
dc.contributor.author |
Pogorelcev Valeriy Ilich |
ru_RU |
dc.date.accessioned |
2006-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2006-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2006 |
ru_RU |
dc.identifier.citation |
Ziyatdinova, G.K.Determination of captopril in pharmaceutical forms by stripping voltammetry / G.K. Ziyatdinova, G.K. Budnikov, V.I. Pogorel'tsev // J. Anal. Chem. - 2006. - V. 61, No.8.- P.798-800. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/eng/?p_id=134870&p_lang=2 |
ru_RU |
dc.description.abstract |
JOURNAL OF ANALYTICAL CHEMISTRY |
ru_RU |
dc.description.abstract |
A voltammetric procedure is developed for determining captopril in pharmaceuticals. It is based on the preliminary electrochemical accumulation of the captopril oxidation product on a platinum electrode in a 0.1 M HNO3 solution at 1.2 V versus a saturated silver?silver chloride electrode. The reduction current of the oxidation product is a linear function of captopril concentration in the range from 1.2×10(?6) to 3.2×10(?4) M. The determination limit is 9.2×10(?7) M. The relative standard deviation is between 1 and 4%. |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
Stripping voltammetry |
ru_RU |
dc.subject |
captopril |
ru_RU |
dc.subject |
pharmaceutical analysis |
ru_RU |
dc.title |
Determination of captopril in pharmaceutical forms by stripping voltammetry |
ru_RU |
dc.type |
Articles in Russian journals and collections |
ru_RU |
|