Form of presentation | Articles in international journals and collections |
Year of publication | 2022 |
Язык | английский |
|
Akhmetov Linar Gimazetdinovich, author
|
Bibliographic description in the original language |
Al, A., Mezan, S. O., , B., Abdullah, M. D., Tesleva, E. et al. (2023). Application of Vortex Generators to Remove Heat Trapped in Closed Channels. FDMP-Fluid Dynamics & Materials Processing, 19(1), 15–24. |
Annotation |
FDMP-Fluid Dynamics & Materials Processing |
Keywords |
Vortex generators; heat trapped; temperature of hot surfaces; heat transfer |
The name of the journal |
FDMP-Fluid Dynamics & Materials Processing
|
URL |
https://doi.org/10.32604/fdmp.2022.019922 |
Please use this ID to quote from or refer to the card |
https://repository.kpfu.ru/eng/?p_id=269767&p_lang=2 |
Full metadata record |
Field DC |
Value |
Language |
dc.contributor.author |
Akhmetov Linar Gimazetdinovich |
ru_RU |
dc.date.accessioned |
2022-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2022-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2022 |
ru_RU |
dc.identifier.citation |
Al, A., Mezan, S. O., , B., Abdullah, M. D., Tesleva, E. et al. (2023). Application of Vortex Generators to Remove Heat Trapped in Closed Channels. FDMP-Fluid Dynamics & Materials Processing, 19(1), 15–24. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/eng/?p_id=269767&p_lang=2 |
ru_RU |
dc.description.abstract |
FDMP-Fluid Dynamics & Materials Processing |
ru_RU |
dc.description.abstract |
The utilization of vortex generators to increase heat transfer from cylinders installed inside a duct is investigated. In particular, a channel containing eight cylinders with volumetric heat sources is considered for different values of the Reynolds number. The effective possibility to use vortex generators with different sizes to increase heat transfer and, consequently, reduce the surface temperature of the cylinders is examined. Also, the amount of pressure drop inside the channel due to the presence of vortex generators is considered and compared with the cases without vortex generators. The results show that although the addition of generators increases the pressure drop, it strongly contributes to increase the heat transfer coefficient inside the duct (up to 80–90%). |