Form of presentation | Articles in Russian journals and collections |
Year of publication | 2007 |
Язык | английский |
|
Budnikov German Konstantinovich, author
Ziyatdinova Guzel Kamilevna, author
|
|
Lapin Anatoliy Andreevich, author
|
Bibliographic description in the original language |
Ziyatdinova, G.K. Direct determination of hypoxen and its analogs by galvanostatic coulometry / G.K. Ziyatdinova, G.K. Budnikov, A.A. Lapin // J. Anal. Chem. - 2007. - V. 62. - No. 3. - P. 260-262. |
Annotation |
A method is developed for determining microgram amounts of antioxidants, i.e., hypoxen and its analogs in model solutions by coulometric titration with electrogenerated halogens using the biamperometric indication of the titration endpoint. The relative standard deviation of the determination varies from 1 to 5%. |
Keywords |
Hypoxen, coulometric titration, electrogenerated halogens |
The name of the journal |
J ANALCHEM+
|
URL |
http://link.springer.com/article/10.1134%2FS1061934807030112 |
Please use this ID to quote from or refer to the card |
https://repository.kpfu.ru/eng/?p_id=66647&p_lang=2 |
Full metadata record |
Field DC |
Value |
Language |
dc.contributor.author |
Budnikov German Konstantinovich |
ru_RU |
dc.contributor.author |
Ziyatdinova Guzel Kamilevna |
ru_RU |
dc.contributor.author |
Lapin Anatoliy Andreevich |
ru_RU |
dc.date.accessioned |
2007-01-01T00:00:00Z |
ru_RU |
dc.date.available |
2007-01-01T00:00:00Z |
ru_RU |
dc.date.issued |
2007 |
ru_RU |
dc.identifier.citation |
Ziyatdinova, G.K. Direct determination of hypoxen and its analogs by galvanostatic coulometry / G.K. Ziyatdinova, G.K. Budnikov, A.A. Lapin // J. Anal. Chem. - 2007. - V. 62. - No. 3. - P. 260-262. |
ru_RU |
dc.identifier.uri |
https://repository.kpfu.ru/eng/?p_id=66647&p_lang=2 |
ru_RU |
dc.description.abstract |
J ANALCHEM+ |
ru_RU |
dc.description.abstract |
A method is developed for determining microgram amounts of antioxidants, i.e., hypoxen and its analogs in model solutions by coulometric titration with electrogenerated halogens using the biamperometric indication of the titration endpoint. The relative standard deviation of the determination varies from 1 to 5%. |
ru_RU |
dc.language.iso |
ru |
ru_RU |
dc.subject |
Hypoxen |
ru_RU |
dc.subject |
coulometric titration |
ru_RU |
dc.subject |
electrogenerated halogens |
ru_RU |
dc.title |
Direct determination of hypoxen and its analogs by galvanostatic coulometry |
ru_RU |
dc.type |
Articles in Russian journals and collections |
ru_RU |
|